技术指标
Power |
4 AA alkaline batteries, provide 50 hours of operation. |
Reverse Battery Protection |
No damage to the tester will occur if the batteries are installed backwards. |
Input Protection |
250 V rms ac, continuous or intermittent |
Moisture |
If the tester is exposed to water, some may get inside, but it will suffer NO DAMAGE. See the information on moisture under “Maintenance”. |
Impedance Range |
35 Ω to 330 Ω with auto-compensation within this range. Cables with an impedance outside this range will not be properly tested and may produce erratic or incorrect readings. |
Maximum Length |
2500 feet on certain cable types, 2000 feet on most cable types, and 500 feet on very lossy cables. The tester will display –Err if the cable is too long to be correctly measured. |
Representative Maximum Cable Length |
2500 feet: CAT-5 Twisted Pair 2000 feet: 12/2 ac Wire 1000 feet: RG-6/U TV Coax 500 feet: RG-174/U Coax |
Minimum Length |
No minimum length Minimum non-zero reading is 2 feet |
Length Accuracy |
±2 feet for cables less than 10 feet ±5 feet for cables longer than 10 feet and shorter than 200 feet ±3 % and ±5 feet for cables longer than 200 feet |
High Voltage Detection |
An ac voltage of more than 5 V rms will trigger the High Voltage Warning. |
Measurement Rate |
Maximum of 4 complete measurements per second, decreasing to 2 seconds per measurement based on cable size and uniformity. |
VOP |
Adjustable from -20- to -99-, retained during power off. Default to -66- when batteries are changed |
Measurement Technology |
Time Domain Reflectometry (TDR) with 50 Ω drive impedance, 6 V maximum pulse height |
Low Battery |
Indicator flashes when battery voltage falls below 4.1 V |
Tone Injection |
Approximately 1 kHz at an amplitude of 80 % of battery voltage. Variable frequency and cadence. Tone characteristic is changed as cable condition changes to “normal-open” from any other condition. |
Cable Type |
Virtually all two or more conductor cables |
Temperature Range | |
Operating Storage |
32 °F to 131 °F (0 °C to 55 °C) -40 °F to 158 °F (-40 °C to 70°C) |
Humidity | |
Operating |
0 % to 80 % |
Storage |
0 % to 100 % |
Weight |
1 lb |
Certifications and Compliance |
Conformité Européenne. Conforms to relevant European Union directives. CAN/CSA-C22.2 No. 60950-1-03 CAN/CSA-C22.2 No. 1010.1-92 CSA-C22.2 No. 1010.1B-97, UL/ANSI 3111-1 |
型号 | 描述 |
26500390 | TS100 linecord, long, ABN/PP clip (general) |
26500000 | TS100 cable fault finder with BNC to alligator clips |
26500500 | TS100 with BNC to banana to ABN |
26500610 | TS100 metric cable fault finder with BNC to alligator clips |
附件
型号 | 描述 |
26501100 | TS100/TS90 linecord, BNC to alligator clip |
26501160 | TS100/TS90 pouch with belt clip |
26501200 | TS100/TS90 linecord, BNC to F(MALE) |
26501300 | TS100/TS90 linecord, BNC to F(FEMALE) |
26501700 | TS100/TS90 linecord, BNC to banana to ABN |
26501600 | TS100/TS90 linecord, banana |